| Power |
|---|
| Output power | 3000 W |
| Input operation voltage (min) | 159 V |
| Input operation voltage (max) | 288 V |
| Output operation voltage (min) | 220 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 2430 J |
| Emergency Power Off (EPO) | Yes |
| Power factor | 1 |
| Output power capacity | 3 kVA |
| Power Factor Correction (PFC) type | Active |
| Ports & interfaces |
|---|
| Cable length | 2.4 m |
| Emergency Power Off (EPO) connector | Yes |
| USB port | Yes |
| Serial interface | Yes |
| Serial interface type | RS-232 |
| AC outlets quantity | 8 AC outlet(s) |
| AC outlet types | C13 coupler, C19 coupler |
| Power plug | C20 coupler |
| RS-232 ports | 1 |
| Ethernet LAN (RJ-45) ports | 2 |
| Performance |
|---|
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| UPS topology | Line-Interactive |
| Waveform | Pure sine |
| Automatic Voltage Regulation (AVR) | Yes |
| Number of output phases | 1 |
| Number of input phases | 1 |
| LED indicators | Fault, Power |
| EMI/RFI noise filtering | Yes |
| Power protection features | Overload |
| Noise level | 57.5 dB |
| Audible alarm(s) | Yes |
| Transfer time (Line Mode to Battery Mode) | 4 ms |
| Features |
|---|
| Output frequency | 50/60 Hz |
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| UPS topology | Line-Interactive |
| Waveform | Pure sine |
| Automatic Voltage Regulation (AVR) | Yes |
| Number of output phases | 1 |
| Number of input phases | 1 |
| Output power | 3000 W |
| Input operation voltage (min) | 159 V |
| Input operation voltage (max) | 288 V |
| Output operation voltage (min) | 220 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 2430 J |
| EMI/RFI noise filtering | Yes |
| Emergency Power Off (EPO) | Yes |
| Power protection features | Overload |
| Power factor | 1 |
| Noise level | 57.5 dB |
| Audible alarm(s) | Yes |
| Output power capacity | 3 kVA |
| Power Factor Correction (PFC) type | Active |
| Transfer time (Line Mode to Battery Mode) | 4 ms |
| Input frequency | 50/60 Hz |
| Battery |
|---|
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 3 h |
| Typical backup time at half load | 6.4 min |
| Typical backup time at full load | 1.3 min |
| Hot-swap battery | Yes |
| Design |
|---|
| Rack capacity | 2U |
| Form factor | Rackmount/Tower |
| LED indicators | Fault, Power |
| Product colour | Black |
| Certification | CE , FCC A , UL , RCM , VCCI |
| Cable length | 2.4 m |
| Housing material | Metal |
| Display type | LCD |
| Operational conditions |
|---|
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Technical details |
|---|
| Output frequency | 50/60 Hz |
| Sustainability certificates | RoHS, ENERGY STAR |
| Harmonized System (HS) code | 85078000 |
| Weight & dimensions |
|---|
| Package width | 560 mm |
| Package depth | 620 mm |
| Package height | 275 mm |
| Weight | 32.3 kg |
| Width | 433 mm |
| Package weight | 40.3 kg |
| Height | 86.5 mm |
| Depth | 500 mm |
| Packaging data |
|---|
| Cables included | Serial, USB cable |
| Package width | 560 mm |
| Package depth | 620 mm |
| Package height | 275 mm |
| Package weight | 40.3 kg |
| Certificates |
|---|
| Certification | CE , FCC A , UL , RCM , VCCI |
| Packaging content |
|---|
| Cables included | Serial, USB cable |